Table 4 Applications of various Drugs, the technique used and the ionization mode in the DART source

From: Application of direct analysis in real-time mass spectrometry (DART-MS) in forensic science: a comprehensive review

Application

Technique

Ionization mode in DART source

Reference

Detection of adulterants and contaminants in drugs

DART ion source coupled to an AccuTOF orthogonal TOF-MS

Both positive and negative ionization mode

(Fernandez and Cody 2006)

DART-TOF (JEOL, Peabody, USA)

Positive ionization mode

(Newton and Fernández 2008; Nyadong and Harris 2009)

AccuTOF -MS (JEOL, Japan) with DART Ion Source (IonSense, USA)

Positive ionization mode

(Chernetsova and Bochkov 2011)

DART-SVP100™ Ion Source (Ionsense, USA) linked with JMS-T100LP AccuTOF (JEOL, Peabody ,USA)

Positive ionization mode

(Samms and Jiang 2011)

DART-SVP™ Ion Source (IonSense, USA) equipped with 6530 Accurate-Mass Quadrupole, TOF-MS (Agilent Technologies, USA)

Positive ionization mode

(Zhou and Zhang 2011)

DART ionization coupled to a QqTOF-MS

Both positive and negative ionization mode

(Vaclavik and Krynitsky 2014)

Determining the active component in several drugs/pharmaceuticals

AccuTOF-DART (JEOL, Peabody, MA) and DART Ion Source (IonSense, USA)

Positive ionization mode

(Ropero-Miller and Stout 2007; Howlett and Steiner 2011; Lesiak and Cody 2014; Chernetsova and Bochkov 2010)

DART-SVP100™ Ion Source (Ionsense, USA) and JMS-T100LP AccuTOF (JEOL, Peabody, USA)

Positive ionization mode

(Likar and Cheng 2011)

AccuTOF-DART-MS (JEOL, Peabody, MA) and DART-SVPTM Ion Source (IonSense, USA)

Positive ionization mode

(Lesiak and Musah 2013; Musah and Cody 2014; Kuki and Nagy 2015)

DART-SVP100™ Ion Source (Ionsense, USA) and JMS-T100LP AccuTOF (JEOL, Peabody, USA)

Positive ionization mode

(Easter and Steiner 2014; Samms and Jiang 2011)

TD-DART-MS interfaced to a JMS-T100LP AccuTOF (JEOL, Peabody, USA)

Positive ionization mode

(Sisco and Verkouteren 2017)

JMS-T100LP AccuTOF (JEOL USA, Peabody, MA) connected to DART-SVPTM Ion Source (IonSense, USA), along with TD-MS

Both positive and negative ionization mode

(Robinson and Sisco 2018)

Identifying drug residuals on surfaces bearing fingerprints or from fluid matrices

DART-SVP100™ Ion Source (Ionsense, USA) and JMS-T100LP AccuTOF (JEOL, Peabody ,USA)

Both positive and negative ionization mode

(Bennett and Steiner 2009; Sisco and Najarro 2018)

A DART® ion source (IonSense, USA) interfaced to AccuTOF® 100 TOF-MS (JEOL, Peabody ,USA)

Positive ionization mode

(Grange and Sovocool 2011)

SALDI-MS using an AXIMA TOF-MS (Shimadzu Pvt. Ltd.) API source from DART Ion Source (IonSense, USA) and JMS-T100LP AccuTOF (JEOL, Peabody ,USA)

Positive ionization mode

(Lim and Rowell 2013)

Identifying marker compounds in herbal drugs

AccuTOF-TLC single-reflectron TOF-MS (JEOL, Peabody ,USA) equipped with a DART Ion Source (IonSense, USA)

Positive ionization mode

(Kim and Jee 2010; Moore and Garvin 2017)

AccuTOF-DART-MS (JEOL, Peabody ,USA) configured with a DART-SVPTM Ion Source (IonSense, USA)

Positive ionization mode

(Lesiak and Musah 2014)

6520 Accurate Mass quadrupole TOF-MS (Agilent Technologies, USA) equipped with a DART SVPTM Ion Source (IonSense, USA)

Positive ionization mode

(Wang and Li 2014)

DART Ion Source (IonSense, Japan) coupled to a JMS-T100TD TLC-TOFMS

Positive ionization mode

(Jang 2009)

Analysis of sexual lubricants

AccuTOF-DART (JEOL, USA)

Positive ionization mode

(Musah and Cody 2012)

DART Ion Source (Ionsense, USA) and JMS-4000LC AccuTOF (JEOL, JAPAN)

Both positive and negative ionization mode

(Maric and Bridge 2016)

DART-SVP100™ Ion Source (Ionsense, USA) and 4G LC- plus AccuTOF (JEOL, Peabody, USA)

Positive ionization mode

(Maric and Harvey 2017)

DART Ion Source (Ionsense, USA) and JMS-4000LC AccuTOF (JEOL, JAPAN)

Both positive and negative ionization mode

(Moustafa and Bridge 2017)

DART-100 Ion Source (Ionsense, USA) and AccuTOF (JEOL)

Both positive and negative ionization mode

(Proni and Cohen 2017)

DART-SVP Ion Source (Ionsense, USA) and JMS-4000LC AccuTOF-LP 4G (JEOL, JAPAN)

Both positive and negative ionization mode

(Baumgarten and Marić 2018)

AccuTOF-DART (JEOL, USA) HRMS with resolving power of 6000 FWHM (full width at half maximum)

Positive ionization mode

(Coon and Beyramysoltan 2019)

DART-SVP Ion Source (Ionsense, USA) and JMS-4000LC AccuTOF-LP 4G (JEOL, JAPAN)

Positive ionization mode

(Bridge and Marić 2019)